ICS CATALOGUE

EXIT DEVICES

MCP330-PRO Resettable Illuminated Call Point with Cover, Activation Sounder and Timer • Operating voltage 12~24Vdc • Green plastic • Resettable • Adjustable sounder • Adjustable LED • Triple pole • Alarmed cover sounder

OPTIONS

MCP330-Pro Key

MCP330-Pro -Cover

MCP330PRO Contact 3 Status: Close Cover MCP330PRO Contact 3 Status: Close Cover

Alarm Mode Settings

Alarm Mode Settings Buzzer LED

LED ON

Buzzer ON

85

N.C. N.O. Com

ON

ON

*

FLASH

BEEP

N.C. N.O. Com

*

FLASH

BEEP

OFF

OFF

*FACTORY SETTING

*FACTORY SETTING

LED

Buzzer

LED

Buzzer

Volume Adjusting Volume Adjusting

VOLUME DELAY

ON OFF FL ON SL BP

VOLUME DELAY

ON OFF FL ON SL BP

Volume

+

Volume

N.C1

+

N.C1

SILENT

SILENT

VCC

N.O1

VCC

N.O1

LOW HIGH LOW HIGH

MCP330PRO Contact 1 & 2 Status CP330PRO Contact 1 & 2 Status

85

GND

COM1

GND

COM1

N.C3

N.C2

N.C3

N.C2

N.O3

N.O2

N.O3

N.O2

Time Delay

Time Delay

N.C. N.O. Com

N.C. N.O. Com

COM3

COM2

COM3

COM2

0~60s

0~60s

+

SILENT

SILENT

Current Input (DC12-24V)

Current Input (DC12- 4V)

LOW HIGH LOW HIGH

Switch Output Point (Max. load of 125VAC/3A)

Switch Output Point (Max. load of 125VAC/3A)

Relay Output Point (Max. load of 125VAC/1A) Relay Output Point (Max. load of 125VAC/1A)

GREEN Display: Standby Status GREEN Display: Standby Status

MCP330PRO Contact 3 Status: Lift Cover MCP330PRO Contact 3 Status: Lift Cover

*Volume switch with maximum value, do not turn in 360. *Volume switch with maximum value, do not turn in 360.

25

N.C. N.O. Com

N.C. N.O. Com

DC12V~24V + DC12V~24V +

LED Buzzer

LED Buzzer

ON OFF FL ON SL BP

VOLUME DELAY

ON OFF FL ON SL BP

VOLUME DELAY

N.C1

N.C1

N.O1

VCC

Power Supply

N.O1

VCC

COM1

GND

MCP330PRO Contact 1 & 2 Status MCP330PRO Contact 1 & 2 Status

Power Supply

COM1

GND

N.C2

N.C3

N.O2

N.O3

N.C2

N.C3

Monitoring System Monitoring System

COM2

COM3

N.O2

N.O3

N.C. N.O. Com

COM2

COM3

N.C. N.O. Com

1. Voice and Green LED flash pre-alert when the cover is lifted, meanwhile the relay output is monitoring by system. 2. The delay time = Cover removing time + delay time (selecting by adjuster) 1. Voice and Green LED flash pre-alert when the cover is lifted, meanwhile the relay output is monitoring by system. 2. The delay time = Cover removing time + delay time (selecting by adjuster)

RED Display: Alarm Status

RED Display: Alarm Status

Exit Devices

146

All dimensions in mm

Made with FlippingBook - professional solution for displaying marketing and sales documents online