ICS CATALOGUE

EXIT DEVICES

MCS-425 Microwave Detector

• Operating voltage 12~24Vdc/Vac • Black ABS plastic

• Microwave • Adjustable • COM / NO / NC Change-over-contacts

Fig A . The Connection for Fail-Safe lock devices

Jumper (N.C.)

+

+

Power Supply

N.C.

N.C. Com. N.O.

122.5

63

72

Control Device

Locking Device (Fail-Safe)

N.C. Com. N.O.

+

Relay Output Control

Fig B . The Connection for Fail-Secure lock devices

Jumper (N.C.)

+

+

Power Supply

N.C.

N.C. Com. N.O.

Locking Device (Fail-Secure)

Control Device

N.C. Com. N.O.

+

Relay Output Control

SPEC I F I CAT ION • Voltage tolerance: ±15%. • Current draw: 80mA (at temperature 20°C.

• Operating temperature: -20 ~ 55°C (-4 to 131°F) . • Frequency: 10.535GHz

• Relay rated: 3A/120Vac; 3A/24Vdc • Relay actuation time: 0.5~4 Seconds • Sensor angle: 7.5 0 ~82.5 0