ICS CATALOGUE

ELECTRIC LOCKING

10040 Monitored Double Standard Magnet

• Operating voltage 12~24Vdc • Aluminium • Fail-Safe (Power to Lock) • Holding force up to 1200lbs x 2 (545Kg x 2) • Surface mount • Status LED ● Red ● Green

OPTIONS

500BP

520S

500ZL

500ZLDC

500AL

500CL

GDB14

10EXTP

LD-SM-SC

252

VOLTAGE SELECTION JUMPERS

Check jumper settings before connecting the lock to 24VDC input power. Damage to the lock may result from incorrect jumper settings.

N.C. Output while door is unlocked; N.O. Output while door is locked by the electromagnetic lock. MAGNET BOND SENSOR OUTPUT

40

530

252

24Vdc

12Vdc

16

STATUS LED: Green: Unlocked Red: Locked Off: No Power

530

6

185

40

N.C.

61

N.O. COM

Sensor Input

16

Power Input SPDT relay

3A@12VDC

+ −

185

67

Coil

Power Supply

+ −

61

Control Device N.C. Contactor or Access relay

SPEC I F I CAT ION • Voltage tolerance: ±15%. • Current draw: 500mA at 12Vdc, 250mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ± 20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C.Output-Door opened; N.O.Output

door closed) (SPDT rated 3A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Special Zinc finish for magnet and armature plate. • Weight: 8.0kg (approx) .

Electric Locking

174

All dimensions in mm

Made with FlippingBook - professional solution for displaying marketing and sales documents online