ICS CATALOGUE

ELECTRIC LOCKING

GK760 MONITORED GK770 UNMONITORED Electric Release • Operating voltage 12~24Vdc/Vac • Fail-Safe/Fail-Secure (Selectable) • Max latch throw 18mm • Door status output • For wood or metal frame doors • Long life solenoid • Suitable for DIN standard lockcases

OPTIONS

GK760- 25 LIP

GK760- 50 LIP

MONITORED

UNMONITORED

FLEXIBLE SOLUTIONS

32

32

14

14

The GK760 electric strike can easily change between Fail-Safe and Fail-Secure modes. This unique design enables distributors to reduce inventory and still meet varying needs and requirements of end users.

3

3

2

201

201

180

180

132.5

132.5

1

160

160

Fail-Secure (Power to Open)

39.5

39.5

121.5

121.5

2

28

28

1

Fail-Safe (Power to Lock)

38.5

38.5

SPEC I F I CAT ION • Voltage tolerance: ±15%. • Current draw: 210mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Reed switch rating: 1A/125Vac • Humidity: 0 ~ 95% non-condensing.

• Tested to 1,000,000 cycles (solenoid) . • Material: Zinc alloy main stand, Stainless Steel face plate. • 1000lbs jaw strength pull testing.

Electric Locking

226

All dimensions in mm

Made with FlippingBook - professional solution for displaying marketing and sales documents online