ICS NEW 2024
Electric Locking
U L 275 SL MONITORED ECO Low Current Mini Magnet
• Operating voltage 12~24Vdc (Selectable) • 250mA @12VDC 130mA @24VDC • Holding force up to 600lbs (272Kg) • Aluminium housing • Electroless Nickel Plated Armature • Fail-Safe • Door status: An independent contact that works separately from the magnet to show
door status not lock status • Status LED ● Red ● Green
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
Contact
+
250
+
N.O.
N.C.
C
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm