ICS PRODCUT CATALOGUE 2026
ElEctric locking
ELECTRIC LOCKING
GK231M-L LEFT HAND GK231M-R RIGHT HAND Monitored Electric Release
• Operating voltage 12 or 24Vdc • Fail-Safe • 1500lbs holding force • 500lbs sideload • 1 Hour UK fire certificate
SIDELOAD 500
LBS
FIRE RESISTANT
STAINlESS STEEl
UK FIRE TESTED
40
56
66
54
Operating Voltage
Power Supply
+ −
+ −
N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1
FAIL-SECURE: N.C. CONTACT FAIL-SAFE: N.O. CONTACT
J2
Lock Status Output
141
(Lock status output: 1/125Vac)
48
48
60
FAIL-SECURE: N.O. CONTACT FAIL-SAFE: N.C. CONTACT
J1
Door Status Output
13
(Door status output: 1/125Vac)
13
23
SpECIFICAtIon • Voltage tolerance: ±20%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Life rating of solenoid valve: 250,000 cycles
• Keeper width: 48mm • Latch throw: 15mm (GK233: 8mm) • Material: Stainless Steel • 1500lbs jaw strength pull testing. • Weight: 673g