ACCESS CONTROL_Part1
A C C E S S C O N T R O L
ACCESS CONTROL
ACCESS CONTROL
DG-101WI DG-101BA Standalone Keypad Access
WHITE
BLACK
• Operating voltage 12~24Vdc • ABS plastic • Allows up to 49+50 PIN codes • Dual relays output for multi control • Fully programmable via keypad and master code • 5 digit codes only • 3 LED displays with audible indication
40
70
12Vdc
+
+
Locking Device 1 (Fail-Safe)
Com.1
N.O.1
N.C.1
Relay
Relay
12Vdc
+
2 3 1
Locking Device 2 (Fail-Secure)
114
+
5 6 4
Push Button 1
Black: N.O.2 Brown: Com.2 Red: N.C.2 Orange: P1 Yellow: B1 Green: P2 Blue: B2 Purple: Reed Grey: Reed
8 9 7
Reset
Master Code reset to Factory 12345
0 #
Push Button 2
1 2 3
Contact door reed switch. This reed switch is used to reset the re-locking time to 0 second when the door is moved (relay 1). Using N.O. contact in case of door closed, change over to N.C. when door is moved.
SPECIFICATION • Current draw: Pull in: 60mA/12Vdc; Holding: 15mA/12Vdc. • Output: Dual relays, N.O./N.C/Com. • Relays rating: 2A@30Vdc., 0.4A@120Vac.
• Memory volume: 49+50 PIN codes. Relay 1 is controlled by 001~049 user slots. Relay 2 is controlled by 050~099 user slots.
All dimensions in mm
Setting the Standard in Access Control
1
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
DG-15LD Standalone Keypad Access • Operating voltage 12~24Vdc • Die-cast Aluminium • Allows up to 20+1 PIN codes • Backlit keypad • Dual relays output for multi-control • Weather resistant • Vandal resistant • 3 LED displays with audible indication
WEATHER RESISTANT
VANDAL RESISTANT
SPECIFICATION • Current draw: Average 15mA, Peak 100mA@12Vdc. • Input: 2 x Request-to-exit, time out reed switch contact. • Output: Dual relays, N.O./N.C/Com. Output (volt free contact) . • Relays Rating: 2A MAX@30Vdc., 0.4A@120Vac. • Fully programmable via keypad and master code. • Factory master code: 12345.
• Memory Volume: 20+1 PIN codes. Relay 1 is controlled by *01~*20 user slots. Relay 2 is controlled by *21 user slots.
• Invalid PIN Lock-out: The system will shut down for 60 seconds while 30 codes of incorrectly Master Codes enrolled or Pin codes attempted (None beeper signal of keypad activations) .
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
2
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
DG-25LD Standalone Keypad Access • Operating voltage 12~24Vdc • Stainless Steel • Allows up to 49+50 PIN codes • Backlight keypad • Dual relays output for multi-control • Weather resistant • Vandal resistant • 3 LED displays with audible indication
WEATHER RESISTANT
STAINLESS STEEL
VANDAL RESISTANT
80
26
Locking Device 2 (Fail-Safe)
+
Power Supply
+
+
Locking Device 1 (Fail-Secure)
+
2 3 1
Power Supply
+
N.O.1 COM N.C.1 REED REED
Contact door reed switch. This reed switch is used to reset the re-locking time to 0 second when the door is moved. (Using N.O. contact in case of door closed, change over to N.C. when door is moved).
N.O.2 COM N.C.2
5 6 4 8 9 7 0 #
P2 B2
P1 B1
Push Button 2
116
Push Button 1
1 2 3
Master Code reset to Factory 12345
P1
SPECIFICATION • Current draw: Average 15mA, Peak 60mA@12Vdc. • Input: 2 x Request-to-Exit, time out reed switch contact. • Output: Dual relays, N.O./N.C/Com. Output (free voltage contact) . • Relays Rating: 2A MAX@30Vdc., 0.4A@120Vac. • Fully programmable via keypad and master code. • PIN codes: 5 digit codes only.
• Memory Volume: 49+50 PIN codes. Relay 1 is controlled by 001~049 user slots. Relay 2 is controlled by 050~099 user slots. • Relays Activation Time: (*100,*200) . Strike Time: 1~99 seconds. Strike mode: Access Timer or Latch.
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
3
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
EPX-20 -WP Combined Proximity and Keypad Access • Operating voltage 12Vdc • ABS plastic • 1000 users • Illuminated • Touch sensitive • Pin / Prox / Pin & Prox • Aux weigand output • LED display
• Weatherproof
For AC/DC
RED
+ 12V
74
BLACK
GND
~ ~
+
BROWN
DATA1
+
ORANGE
DATA0
For DC use only
GREY
Button
PINK
LED
2 3 1
BLUE
Normal Close
114
PURPLE
5 6 4
COM
GREEN
NO-Normal
EPX20 Keypad Access
8 9 7
YELLOW
Bell
8 ohm 0.5W
WHITE
GND
0 #
+ 12V PINK
LED YELLOW BELL PURPLE COM
RED
17
BLACK
GND WHITE
GND BROWN DATA1
BLUE NORMAL
GREEN
N.O.
ORANGE DATA0
GREY BUTTON
SPECIFICATION • Current draw: Pull in: 100mA/12Vdc; Holding: 70mA/12Vdc. Pull in: 50mA/24Vdc; Holding: 35mA/24Vdc. • Input: Request-to-Exit, time out reed switch contact. • Output: Dual relays, N.O./N.C/Com. • Relays rating: 2A MAX@30Vdc., 0.6A@120Vac.
• Programmable 4 digit code. • RF frequency: EM 125 KHz. • Relay strike time: 01~99 seconds or toggle mode (00) . • Read range: 5cm. (In noise -free environment) .
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
4
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
KP-500 Combined Proximity and Keypad Access
• Operating voltage 12Vdc • Die-cast metal • Allows up to 1000+1 proximity cards, tokens and PIN’s
• Backlit keypad • 2 LED displays
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
27
Power Supply
+
76
AUX RELAY
Com N.C N.O
Com N.C N.O
Change from NC to NO for use with FAIL SECURE LOCK
+
2 3 1 5 6 4 8 9 7 0 #
+12V
GND
PUSH/NO
OPENSW
DOOR1 BELL
BELL
AUX IN GND
+12V
GND
DATA0
DATA1
120
+
12 Vdc Power Supply
Reed Switch
Exit Button
Open SW - GND: Exit button connection (Button must be N/O going closed). Aux IN - GND: A N/O going closed input that activates the aux relay and sounds an internal alarm when connection made. Door1 - GND: Reed switch connections must be N/C when the door is closed. If the door is left open an internal alarm will sound when the door sensor mode is enabled. The time can be adjusted using the alarm delay time settings.
Bell-Bell:
A N/O connection going closed when the bell button is pressed.
SPECIFICATION • Output: 1 relay COM/NO/NC. • Programmable 4 digit code. • RF Frequency EM 125 KHz.
• Relay strike time 01~99 seconds. • Read range 5cm. (In noise -free environment) .
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
5
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL ACCESS CONTROL
DG 800 -N Combined Proximity and Keypad Access DG 800 -N-BLK Combined Proximity and Keypad Access DG 800N Combined Proximity and Keypad Access • Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • Backlit keypad • Weather resistant: IP65 • Vandal resistant • Terminal connections • Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • Backlit keypad • Weather resistant: IP65 • Vandal resistant • 2 LED displays with audible indication • Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • White Backlit keypad • W aterproof: IP 66 • Vandal resistant • 2 LED displays with audible indication
Waterproof WEATHER RESISTANT − IP 65 − − IP 6 6 −
VANDAL RESISTANT VANDAL RESISTANT
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
OPTIONS
STD-PC
STD-PCPS
KT-10BC
KT-15EM
KT-16
621-11
For AC/DC
21
12/24Vdc
Red
+ −
76
~ ~
12/24Vdc
Black
+
REED
Brown
For AC/DC For AC/DC
21
21
+
+ −
12VDC Power Supply +
+ −
+
PB1
Grey
12VDC Power Supply
For DC use only
76
PB2
Orange
76
~ ~
~ ~
+
+
N.C.1
+
N.C.1
N/O1
Green
2 3 1 5 6 4 8 9 7 0 #
Electric Lock 1 (Fail-Safe)
Electric Lock 1 (Fail-Safe)
+
COM 1
COM 1
Varistor
COM1
Purple
Varistor
N.O.1
For DC use only For DC use only
N.O.1
N/C1
Blue
(MUST install a Varistor)
120
(MUST install a Varistor)
PB1
Exit Button 1
PB1
Exit Button 1
N/O2 Stand Alone Reader
Green/White
2 3 1 5 6 4 8 9 7 0 #
2 3 1 5 6 4 8 9 7 0 #
PB2
Exit Button 2
PB2
Exit Button 2
COM2
Purple/White
REED
Door Closed=N.O. Door Opened=N.C.
REED
REED
Door Closed=N.O. Door Opened=N.C.
REED
+
N/C2
Blue/White
+
120
N.C.2
120
N.C.2
Electric Lock 2 (Fail-Secure)
▲
Diode
Electric Lock 2 (Fail-Secure)
COM 2 Stand Alone Reader Stand Alone Reader COM 2
▲
Diode
+
(MUST install a Diode)
PURPLE/ WHITE
RED
GREY
PB1
PURPLE COM1
COM.2
N.O.2
+
(MUST install a Diode)
N.O.2
12VDC Power Supply +
-
BLUE/ WHITE
ORANGE PB2
BLUE
N/C1
N.C.2
BLACK
GND
12VDC Power Supply
GND
GREEN/ WHITE
BROWN REED
GREEN N/O1
N/O2
+
RED
PINK COM. 1
YELLOW PB2
PURPLE COM.2
+
-
BLACK RED
PINK COM. 1
YELLOW PB2
PURPLE COM.2
WHITE
N.O.1
BROWN REED
BLUE
N.O.2
-
LIGHT GREEN
ORANGE PB1 WHITE
N.O.1
BROWN REED
BLUE
N.O.2
BLACK
N.C.1
GREY
N.C.2
GREEN GND
Setting the Standard in Access Control
43
LIGHT GREEN
N.C.1
ORANGE PB1
GREY
N.C.2
GREEN GND
2933_ICS_Catalogue_Update_2018.indd 43
07/01/2019 14:44
ACCESS CONTROL Setting the Standard in Access Control 6
All dimensions in mm
All dimensions in mm | Setting the Standard in Access Control ACCESS CONTROL
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
ACCESS CONTROL
DG 800 -N-BLK Combined Proximity and Keypad Access
• Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • White Backlit keypad • W aterproof: IP 66 • Vandal resistant • 2 LED displays with audible indication
VANDAL RESISTANT
Waterproof
− IP 6 6 −
For AC/DC
21
+ −
+
12VDC Power Supply
76
~ ~
+
+
N.C.1
Electric Lock 1 (Fail-Safe)
+
COM 1
Varistor
N.O.1
For DC use only
(MUST install a Varistor)
PB1
Exit Button 1
2 3 1 5 6 4 8 9 7 0 #
PB2
Exit Button 2
REED
Door Closed=N.O. Door Opened=N.C.
REED
+
120
N.C.2
Electric Lock 2 (Fail-Secure)
▲
Diode
COM 2 Stand Alone Reader
(MUST install a Diode)
N.O.2
+
12VDC Power Supply
GND
+
RED
PINK COM. 1
YELLOW PB2
PURPLE COM.2
-
WHITE
N.O.1
BROWN REED
BLUE
N.O.2
BLACK
LIGHT GREEN
N.C.1
ORANGE PB1
GREY
N.C.2
GREEN GND
7
ACCESS CONTROL
All dimensions in mm
Setting the Standard in Access Control All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL ACCESS CONTROL
DG160 N-BLK Combined Proximity and Keypad Access
• Operating voltage 12Vdc • Aluminium • Allows up to 1000+10 proximity cards, tokens and PIN’s • Blue Backlit keypad • Built in anti-tamper switch • 2 LED displays
WATERPROOF
VANDAL RESISTANT
− IP 6 6 −
24
For AC/DC
44
+ −
+
12VDC Power Supply
~ ~
+
+
N.C.1
2 3 4 5 6 7 8 9 0 1 #
Electric Lock 1 (Fail-Safe)
+
COM 1
Varistor
For DC use only
N.O.1
(MUST install a Varistor)
PB1
Exit Button 1
PB2
Exit Button 2
152
REED
Door Closed=N.O. Door Opened=N.C.
REED
+
N.C.2
Electric Lock 2 (Fail-Secure)
▲
Diode
COM 2 Stand Alone Reader
(MUST install a Diode)
N.O.2
+
12VDC Power Supply
GND
+
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
-
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
All dimensions in mm
ACCESS CONTROL Setting the Standard in Access Control
ACCESS CONTROL
8
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
KTP 12 Series Piezoelectric System Keypads • Operating voltage 5 or 12Vdc • Heavy duty • Single gang or mullion mount • Industry standard outputs available • No moving parts to wear out • Laser marked keypad graphics • Weather resistant: IP65 • Vandal resistant • Limited lifetime warranty
Essex Electronics
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
ORDERING GUIDE
A CHOOSE OUTPUT
B INDICATE MATRIX
EXAMPLES
10 16 17 19 22 32 40
26 Bit Wiegand
3
12 Pad 3x4
A OUTPUT
C FINISH/STYLE
8 Bit Word ABA Track II
C CHOOSE VOLTAGE
Infrared/Bar Code
KTP 10 3 SN
BCD
B MATRIX
(X-Y or 2 of 7 only)
X-Y Row and Column
5
5 Volt
2 of 7 485 RS-485 98
12
12 Volt
Serial ASCII 1000 HID Corporate 1000
A OUTPUT
C VOLTAGE
D CHOOSE FINISH/STYLE XX No Bezel SN Stainless Steel Bezel KN Black Bezel BN Brass Finished Bezel
KTP 32 3 12 SN
CUSTOM OUTPUTS AVAILABLE
B MATRIX
D FINISH/STYLE
26 Bit Wiegand: Field Programmable Site Code (000-255). Serial ASCII: Field Selectable Baud Rate (up to 19.2kps) Parity Option (None, Odd or Even). RS-485: Field Selectable Baud Rate (up to 115.2kps) Parity Option, Polling or Event Mode).
Actual bezel is Stainless Steel with long lasting Brass appearance PVD coating.
SPECIFICATION • Voltage tolerance: ±15%.
• Input voltage: 5 or 12V field selectable (Except X-Y and 2 or 7 outputs) . • Keypad switch lifcycle: >1 Billion Cycles. • Operating temperature: -40 ~ 70°C (-40 to 160°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on
• Standby current draw: <20mA Non illuminated, <60mA illuminated (at temperature 20°C) .
• Humidity: 100% relative. • Weight: 454g (approx) .
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
9
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL ACCESS CONTROL
DG160 N Combined Proximity and Keypad Access
• Operating voltage 12Vdc • Aluminium • Allows up to 1000+10 proximity cards, tokens and PIN’s • Backlit keypad • Built in anti-tamper switch • 2 LED displays
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
24
For AC/DC
44
+ −
+
12VDC Power Supply
~ ~
+
+
N.C.1
2 3 4 5 6 7 8 9 0 1 #
Electric Lock 1 (Fail-Safe)
+
COM 1
Varistor
For DC use only
N.O.1
(MUST install a Varistor)
PB1
Exit Button 1
PB2
Exit Button 2
152
REED
Door Closed=N.O. Door Opened=N.C.
REED
+
N.C.2
Electric Lock 2 (Fail-Secure)
▲
Diode
COM 2 Stand Alone Reader
(MUST install a Diode)
N.O.2
+
12VDC Power Supply
GND
+
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
-
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
ACCESS CONTROL Setting the Standard in Access Control 10
All dimensions in mm | Setting the Standard in Access Control ACCESS CONTROL
All dimensions in mm
ACCESS CONTROL
E3AK7 + Keypad and Bluetooth • Operating voltage 12~24Vdc • Diecast metal • Bluetooth
• Backlit keypad • Vandal resistant • Built in tamper alarm and buzzer (85dB) • Weather resistant: IP65 • 2 LED displays with audible indication
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
BLUETOOTH
22
76
2 3 1 5 6 4 8 9 7 0 #
Reset Procedures 1. Power o Access Control Keypad.
120
2. Move the pin Jumper to P2 and P3, then power on. 3. Hear a long beep to complete resetting procedures. 4. Move the Pin jumper back to P1 and P2 to Normal setting. 5. Login as Admin and check all users, audit trail events are all cleared and everthing is reset to factory default settings, except device name.
LED STATUS BLUE POWER ON, STANDBY MODE
AUDIBLE BEEPS
STATUS
1 SHORT BEEP KEY PRESS 1 LONG BEEP VALID ACCESS, RESET IS COMPLETE 2 SHORT BEEPS LOCKING COMPLETE 3 SHORT BEEPS INVALID ACCESS CONSTANT BEEPING BLUETOOTH DEVICE VANDALISED DOOR SENSOR IS ON
GREEN UNLOCKED, DOOR ALWAYS UNLOCKED RED INVALID ACCESS, DOOR ALWAYS LOCKED
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
11
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
DG800 + Combined Proximity and Keypad Access
• Operating voltage 12Vdc • Die-cast Aluminium • Bluetooth • Backlit keypad • Weather resistant: IP65 • Vandal resistant • Multiple LED display with audible indication
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
BLUETOOTH
79
DG800+
DG160+
(DG800+ & DG160+ have same wiring and pin setting)
120
LED STATUS BLUE POWER ON, STANDBY MODE
AUDIBLE BEEPS
STATUS
1 SHORT BEEP KEY PRESS 1 LONG BEEP VALID ACCESS, RESET IS COMPLETE 2 SHORT BEEPS LOCKING COMPLETE 3 SHORT BEEPS INVALID ACCESS CONSTANT BEEPING BLUETOOTH DEVICE VANDALISED DOOR SENSOR IS ON
GREEN UNLOCKED, DOOR ALWAYS UNLOCKED RED INVALID ACCESS, DOOR ALWAYS LOCKED
21
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
12
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
DG-850-TH-G Standalone Keypad Access
• Operating voltage 12Vdc • Die-cast Metal • Allows up to 20+1 PIN codes • Touch Panel keypad • Dual relays output for multi-control • Weather resistant • 4 or 5 Digit Codes • 3 LED displays with audible indication
WEATHER RESISTANT IP 65
VANDAL RESISTANT
SPECIFICATION • Current draw: Average 70mA, Peak 90mA@12VDC. • Input: 1 x Request-to-exit, time out reed switch contact • Output: Dual relays, N.O./N.C/Com. Output (volt free contact). • Relays Rating: 2A MAX@30VDC., 0.4A@120VAC. • Fully programmable via keypad and master code.
+
Power Supply
INPUT 12~24VDC N.O.1 COM. 1 N.C.1
Electric Lock 1 Fail-Safe Mode
(Must install a Varistor)
+
PB PB
Dry Contact
+ +
Power Supply
• Factory master code: 12345 -1234. • Memory Volume: 20+1 PIN codes. Relay 1 is controlled by *01~*20 user slots. Relay 2 is controlled by *21 user slots.
N.O.2 COM.2
N.C.2 REED REED
Electric Lock 2 Fail-Safe Mode
• Invalid PIN Lock-out: The system will shut down for 60 seconds while 30 codes of incorrectly Master Codes enrolled or Pin codes attempted ( None beeper signal of keypad activations).
(Must install a Diode)
4 or 5 Reset
N.C Contact Output: Open Status N.O. Contact Output: Closed Status
2 15/16” (76mm)
13/16” (21mm)
For AC/DC
For DC use only
The door strike or relay must have a Varistor or a Diode across the door strike terminals to suppress the back EMF of the strike-failure to do so will damage the relay contacts and electronic components, or even burns the controller.
4 3/4” (120mm)
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
13
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL ACCESS CONTROL ACCESS CONTROL
DG -365-PLUS Proximity Access DG -365-PLUS Proximity Access
• Operating voltage 12Vdc • Die-cast Metal • Bluetooth • Weather resistant: IP65 • Vandal resistant • Multiple LED display with audible indication • Operating voltage 12Vdc • Die-cast Metal • Bluetooth • Weather resistant: IP65 • Vandal resistant • Multiple LED display with audible indication
WEATHER RESISTANT − IP 65 −
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
VANDAL RESISTANT
BLUETOOTH
BLUETOOTH
3” (76mm)
3” (76mm)
Red (+)
Red (+)
+
+
Item 1 2 3 4 5 6 7 8 9
Item 1 2 3 4 5 6 7 8 9
Wire Color Terminal
Wire Color Terminal
Description
Description
Power Supply
Power Supply
12VDC
12VDC
Black (-) Yellow (N.C.)
Black (-) Yellow (N.C.)
-
-
Red Black Blue White Yellow Green Green
Red Black Blue White Yellow Green Green
+ - N.O. COM N.C. PB
+ - N.O. COM N.C. PB
Positive Negative
Positive Negative
+
+
Electric Lock1
Electric Lock1
Diode
Diode
Fail-Safe
Fail-Safe
White (COM)
White (COM)
-
-
(Must install diode) Diode
(Must install diode) Diode
SSR contact
SSR contact
+
+
Blue (N.O.)
Blue (N.O.)
Electric Lock 2 Fail-Secure Fail-Secure
Electric Lock 2
-
-
Green (P.B.)
Green (P.B.)
(Must install diode)
(Must install diode)
RTE contact
RTE contact
120mm 4 3/4” 4 3/4”
PB DS
PB DS
Green (P.B.)
Green (P.B.)
RTE (Dry contacts)
RTE (Dry contacts)
Orange Orange
Orange Orange
Orange (DS) Orange (DS)
Orange (DS) Orange (DS)
120mm
Door sensor (REED)
Door sensor (REED)
LED Indicator
LED Indicator
Door Sensor (REED)
Door Sensor (REED)
DS ALM ALM
DS ALM ALM
10 11
10 11
Brown (ALARM) Brown (ALARM)
Brown (ALARM) Brown (ALARM)
Brown Brown
Brown Brown
Tamper alarm output contact
Tamper alarm output contact
Tamper Alarm Output (Dry contacts)
Tamper Alarm Output (Dry contacts)
Logo Indicator
Logo Indicator
21mm 13/16”
21mm 13/16”
All dimensions in mm
All dimensions in mm
Setting the Standard in Access Control Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
ACCESS CONTROL
14
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL ACCESS CONTROL
ACCESS CONTROL
• • Operating voltage 12Vdc • Black ABS plastic • Bluetooth • Internal or external use • Self-contained • EASIPROX + Standalone Proximity • Operating voltage 12Vdc • Black ABS plastic • Bluetooth • Internal or external use • Self-contained EASIPROX + Standalone Proximity
• Read range 5cm • Fully programmable via master card • 3 LED displays with audible indication • Weather resistant: IP67 • Read range 5cm • Fully programmable via master card • 3 LED displays with audible indication • Weather resistant: IP67
WEATHER RESISTANT − IP 67 −
BLUETOOTH
WEATHER RESISTANT − IP 67 −
BLUETOOTH
18
18
80
80
114
114
LED POWER + DC12-15V BLUE POWER ON, STANDBY MODE LED POWER + DC12-15V BLUE POWER ON, STANDBY MODE
AUDIBLE BEEPS STATUS 1 LONG BEEP VALID ACCESS, RESET IS COMPLETE 2 SHORT BEEPS LOCKING COMPLETE 3 SHORT BEEPS INVALID ACCESS CONSTANT BEEPING BLUETOOTH DEVICE VANDALISED DOOR SENSOR IS ON AUDIBLE BEEPS STATUS 1 LONG BEEP VALID ACCESS, RESET IS COMPLETE 2 SHORT BEEPS LOCKING COMPLETE 3 SHORT BEEPS INVALID ACCESS CONSTANT BEEPING BLUETOOTH DEVICE VANDALISED DOOR SENSOR IS ON
GREEN UNLOCKED, DOOR ALWAYS UNLOCKED RED INVALID ACCESS DOOR ALWAYS LOCKED GREEN UNLOCKED, DOOR ALWAYS UNLOCKED RED INVALID ACCESS DOOR ALWAYS LOCKED
All dimensions in mm
Setting the Standard in Access Control Setting the Standard in Access Control
ACCESS CONTROL
All dimensions in mm
ACCESS CONTROL
15
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
SPLIT II Standalone Proximity
• Operating voltage 12 or 24Vac/Vdc • 2000 users relay 1 • 100 users relay 2 • Infra-red programmer • Reads EM, Mifare and HID cards • IMPORTANT: Cards for relay 1 do not work on relay 2
INFRA-RED
Select the lock according to the need.
Alarm
+ –
Magnetic Lock or Fail-Safe Lock Select the lock according to the need.
J1
+ –
NC1 COM1
ALARM + ALARM –
1 2
4 3
IR
LED
GND NO1
1N4004 1N4004 1N4004 1N4004
+ – Gate/Door Operator or Fail-Secure Lock Magnetic Lock or Fail-Safe Lock + –
+ 12v GND Power + – Power + 12v GND
Alarm
Lock 1
+ 12v ALARM + ALARM – GND
J2 J1
NC2 COM2 NC1 COM1 GND NO1 NC2 COM2 NO2 OPEN1 GND OPEN2 GND NO2 OPEN1 GND OPEN2 GND D_IN
1 2 1 2
4 3 4 3
IR
LED
Power Alarm
Red Black
+ – Gate/Door Operator or Fail-Secure Lock
Lock 2 Exit Lock 1 Lock 2 Exit
D0 D1 LED1 BEEP1 LED2 BEEP2 + 12v GND D0 D1 LED1 BEEP1 LED2 BEEP2 + 12v GND D0 D1 LED2 BEEP2 + 12v GND D0 D1 LED2 BEEP2
J2
Sboard-II
Exit Button of Zone 1 Exit Button of Zone 2 Exit Button of Zone 1 Exit Button of Zone 2 Door Status Detecting
Green White Brown Yellow Red Black Green White Brown Yellow Green White Brown Yellow Red Black Green White Brown Yellow Red Black
1 2
4 3
Power Alarm
Sboard-II
Reader
Reader 1
Door
Contact
GND D_IN
Reader
Door Status Detecting
Reader 1
Door
Attention: Install a 1N4004 or equivalent diode is needed when using a common power supply, or the controller might be damaged. (1N4004 is included in the packaging). Attention: Install a 1N4004 or equivalent diode is needed when using a common power supply, or the controller might be damaged. (1N4004 is included in the packaging). Contact
Reader 2
Reader 2
WHEN USING NO/NC/COM DRY CONTACT OUTPUT
J1
NC1 COM1
ALARM + ALARM –
1 2
4 3
PRODUCT
DESCRIPTION
LED
IR
GND NO1
Lock 1
+ 12v ALARM + ALARM – GND
J2 J1
NC2 COM2 NC1 COM1 GND NO1 NC2 COM2 NO2 OPEN1 GND OPEN2 GND NO2 OPEN1 GND OPEN2 GND D_IN
Split Controller with Mullion Reader
SPLIT II-M
1 2
4 3 4 3
1. Remove the Pin Caps on points 1, 2, 3 and 4 (Remark: J1 (Relay 1) & J@ (Relay2), please check the relay you are using). 2. Insert one of the Pin Caps on point 1 and point 4. 3. Fix the back cover and keep the other Pin Cap well. 1. Remove the Pin Caps on points 1, 2, 3 and 4 (Remark: J1 (Relay 1) & J@ (Relay2), please check the relay you are using). 2. Insert one of the Pin Caps on point 1 and point 4. 3. Fix the back cover and keep the other Pin Cap well.
Sboard-II 1 2 IR LED Sboard-II 1 2
Power Alarm Reader Power Alarm Reader
Lock 2 Exit Lock 1 Lock 2 Exit
Split Controller with 2 x Mullion Reader
SPLIT II-M-2
D0 D1 LED1 BEEP1 LED2 BEEP2 + 12v GND D0 D1 LED1 BEEP1 LED2 BEEP2
J2
4 3
Split Controller with wall Reader
SPLIT II-W
Controller Only
SBOARD II
Door
Mullion Multi-Tech Reader
MR-900
Contact
GND D_IN
Wall Mount EM Reader
EM-901
Door
Contact
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
16
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
EPX-10 Standalone Proximity • Operating voltage 12Vdc • ABS plastic • Allows up to 2000 users • Weather resistant: IP67 • Infrared programmer
WEATHER RESISTANT − IP 65 −
75
Red
+
Power Supply
Black
Brown
115
Unlocking Button
Orange
RED POWER + DC12-15V
Yellow
BLACK
POWER GND
BROWN UNLOCKING BUTTON
Green
ORANGE
N.C.
Grey
YELLOW
COM.
GREEN
N.O.
White
21
GRAY
485+
WHITE
485−
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
17
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
EPX10-HP Infrared Programmer
• Operating voltage : 2 x AAA Batteries • For Programming EPX Readers
All dimensions in mm
Setting the Standard
ACCESS CONTROL
18
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
One K1 Single Door Access Kit
One Door, One Box, One Solution!
KIT CONTENTS
1 x DG-15LD digital keypad, 21 users 1 x 12Vdc, 1Amp boxed power supply 1 x M1 lock, fail-secure electric release
1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit
Setting the Standard in Access Control All dimensions in mm
ACCESS CONTROL
19
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
One K2 Single Door Access Kit
One Door, One Box, One Solution!
KIT CONTENTS
1 x DG-15LD digital keypad, 21 users 1 x 12Vdc, 1Amp boxed power supply 1 x U10001 magnetic lock 1 x U300ZL Z&L bracket
1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
20
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
One K3 Single Door Access Kit
One Door, One Box, One Solution!
KIT CONTENTS
1 x EPX10 proximity system, 2000 users
1 x 12Vdc, 1Amp boxed power supply 1 x M1 lock, fail-secure electric release
1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit 10 x KT10BC tokens 1 x EPX10-HP
RED POWER + DC12-15V
BLACK
POWER GND
75
BROWN UNLOCKING BUTTON
ORANGE
N.C.
YELLOW
COM.
GREEN
N.O.
Red
+
Power Supply
115
Black
Brown White
Exit Button
1 2 3
Call Point
Orange
Yellow
Varistor
Green
21
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
21
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
One K4 Single Door Access Kit
One Door, One Box, One Solution!
KIT CONTENTS
1 x EPX10 proximity system, 2000 users 1 x 12Vdc, 1Amp boxed power supply 1 x U10001 magnetic lock 1 x U300ZL Z&L bracket
1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit 10 x KT10BC tokens 1 x EPX10-HP
RED POWER + DC12-15V
BLACK
POWER GND
75
BROWN UNLOCKING BUTTON
ORANGE
N.C.
YELLOW
COM.
GREEN
N.O.
Red
+
Power Supply
115
Black
Brown White
COM
2 Way
Exit Button
1 2 3
Call Point
Orange
Yellow
Varistor
Green
21
+
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
22
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
One K5 Single Door Access Kit DG160 N-BLK Combined Proximity and Keypad Access One Door, One Box, One Solution! 1 x DG1 6 0 digital keypad, 1000 users 1 x 12Vdc, 2Amp boxed power supply 1 x M1 lock, fail-secure electric release 1 x • Operating voltage 12Vdc • Aluminium • Allows up to 1000+10 proximity cards, tokens and PIN’s • Blue Backlit keypad • Built in anti-tamper switch • 2 LED displays DRB001N-PTE exit button 1 x CP21-N break-glass unit KIT CONTENTS
WATERPROOF
VANDAL RESISTANT
− IP 6 6 −
6.7
24
For AC/DC
44
Red Black
Rechargeable Battery
44
+ −
+
12VDC Power Supply
+
+
DC OUT
Battery
Black + Brown = Reed
~ ~
+
Door Closed = N.O. Door Open = N.C.
+
N.C.1
2 3 4 5 6 7 8 9 0 1 #
16VAC IN Electric Lock 1 (Fail-Safe)
+
+
12VDC IN
White COM 1
Power Supply
Varistor
C1 C2 GND LOCK1 12VDC1 REX1 GND LOCK2 12VDC2 REX2
2 3 4 5 6 7 8 9 0 1
For DC use only
N.O.1
Brown
(MUST install a Varistor)
PB1
Exit Button 1
1 2 3
Stand Alone Reader
Call Point
PB2
Exit Button 2
152
Varistor
REED
Door Closed=N.O. Door Opened=N.C.
REED
150
+
N.C.2
COM
2 Way
Electric Lock 2 (Fail-Secure)
▲
Diode
COM 2 Stand Alone Reader
(MUST install a Diode)
Exit Button
N.O.2
+
12VDC Power Supply
GND
#
+
For AC/DC
For DC use only
+
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
~ ~
-
+
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
23
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
One K6 Single Door Access Kit
One Door, One Box, One Solution!
KIT CONTENTS
1 x DG1 6 0 digital keypad, 1000 users 1 x 12Vdc, 2Amp boxed power supply
1 x U10001 magnetic lock 1 x U300ZL Z&L Bracket 1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit
24
For AC/DC
44
+ −
+
12VDC Power Supply
~ ~
+
+
N.C.1
2 3 4 5 6 7 8 9 0 1 #
Electric Lock 1 (Fail-Safe)
+
COM 1
Varistor
For DC use only
N.O.1
(MUST install a Varistor)
PB1
Exit Button 1
PB2
Exit Button 2
152
REED
Door Closed=N.O. Door Opened=N.C.
REED
+
N.C.2
Electric Lock 2 (Fail-Secure)
▲
Diode
COM 2 Stand Alone Reader
(MUST install a Diode)
N.O.2
+
12VDC Power Supply
GND
+
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
-
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
24
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
One K7 Access Control Kits
DG 800N Combined Proximity and Keypad Access
One Door, One Box, One Solution!
KIT CONTENTS
1 x DG800 proximity system, 2000 users • Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • Backlit keypad • Weather resistant: IP65 • Vandal resistant • Terminal connections • 2 LED displays with audible indication 1 x 12Vdc, 1Amp boxed power supply 1 x M1 lock, fail-secure electric release 1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit 10 x KT10BC tokens
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
OPTIONS
STD-PC
STD-PCPS
KT-10BC
KT-15EM
KT-16
621-11
For AC/DC
21
For AC/DC
+ RED − BLACK Red Black
12/24Vdc
+
+ −
21
12VDC Power Supply
76
~ ~
12/24Vdc
+
~ ~
76
+
N.C.1
REED
Brown
+
COM 1
PB1
Grey
+
3 2 1
For DC use only
Call Point
N.O.1 WHITE Orange
PB2
For DC use only
PB1 ORANGE
Varistor +
N/O1
Green
2 3 1 5 6 4 8 9 7 0 #
PB2
2 3 1 5 6 4 8 9 7 0 #
COM1
Purple
REED
N/C1
Blue
120
N.C.2
N/O2 Stand Alone Reader
Green/White
120
COM 2
COM2
Purple/White
DG800 KEYPAD / READER N.O.2
N/C2
Blue/White
COM
Exit Button
GND
2 Way
+
PURPLE/ WHITE
RED
GREY
PB1
PURPLE COM1
COM.2
+
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
-
BLUE/ WHITE
ORANGE PB2
BLUE
N/C1
N.C.2
BLACK
-
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
GREEN/ WHITE
BROWN REED
GREEN N/O1
N/O2
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
25
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control Setting the Standard in Access Control 43
ACCESS CONTROL
ACCESS CONTROL
One K8 Access Control Kits
DG 800N Combined Proximity and Keypad Access
One Door, One Box, One Solution!
KIT CONTENTS
1 x DG800 proximity system, 2000 users 1 x 12Vdc, 1Amp boxed power supply 1 x U10001 magnetic lock 1 x U300ZL Z&L Bracket 1 x DRB001N-PTE exit button 1 x CP21-N break-glass unit 10 x KT10BC tokens • Operating voltage 12~24Vac/Vdc • Die-cast Aluminium • 1000+10 Proximity cards, tokens and PIN’s • Backlit keypad • Weather resistant: IP65 • Vandal resistant • Terminal connections • 2 LED displays with audible indication
WEATHER RESISTANT − IP 65 −
VANDAL RESISTANT
OPTIONS
STD-PC
STD-PCPS
KT-10BC
KT-15EM
KT-16
621-11
For AC/DC
21
For AC/DC
12/24Vdc
+ RED − BLACK Red Black
21
+ −
+
12VDC Power Supply
76
~ ~
12/24Vdc
+
~ ~
76
+
REED
N.C.1 GREEN Brown
+
PB1
COM 1 PINK Grey
+
1 2 3
For DC use only
Call Point
N.O.1
PB2
Orange
For DC use only
PB1 ORANGE Green
N/O1
2 3 1 5 6 4 8 9 7 0 #
Varistor
PB2
2 3 1 5 6 4 8 9 7 0 #
COM1
Purple
+
REED
N/C1
Blue
120
N.C.2
N/O2 Stand Alone Reader
Green/White
120
COM 2
COM2
Purple/White
COM
DG800 KEYPAD / READER N.O.2
Exit Button
N/C2
Blue/White
2 Way
GND
+
PURPLE/ WHITE
RED
GREY
+ PB1 -
PURPLE COM1
COM.2
RED
PINK COM. 1 YELLOW PB2
PURPLE COM.2
-
BLUE/ WHITE
ORANGE PB2
BLUE
N/C1
N.C.2
BLACK
WHITE
N.O.1
BROWN REED BLUE
N.O.2
BLACK
GREEN/ WHITE
BROWN REED
GREEN N/O1
N/O2
LIGHT GREEN N.C.1 ORANGE PB1
GREY
N.C.2
GREEN GND
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
26
All dimensions in mm | Setting the Standard in Access Control
Setting the Standard in Access Control
43
ACCESS CONTROL
MDL-01 Mechanical Door Lock
• Zinc Alloy • Remove lock from door to change code • Code in / Code out: No • Single code storage only • For door thickness 35-65mm (13/8"-21/2") • For left or right handed doors • 2 part 8mm (5/16") spring loaded spindle • Internal or external use • Type to front and back plates only
25
32
42
1 2 3 4 5 X Y
6 7 8 9 0 Z C
142
60
40
16
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
27
ACCESS CONTROL
All dimensions in mm | Setting the Standard in Access Control
ACCESS CONTROL
Access Control Accessories, Cards, Tags and Tokens
ICS Security Solutions supply a range of cards, tags, tokens and accessories that work in conjunction with our range of access control products.
ACCESS CONTROL
EPX10-HP Infrared for use with EPX-10 and EPX-30.
STD-PC Proximity Card. Printed number. EM chipset. Access Control Accessories, Cards, Tags and Tokens
STD-PCPS Proximity card. Printed number. EM chipset. With punched slot.
ICS Security Solutions supply a range of cards, tags, tokens and accessories that work in conjunction with our range of access control products.
EPX10-HP Infrared for use with EPX-10 and EPX-30.
KT-15EM Key ring proximity tag. Printed number. EM chipset. STD-PC Proximity Card. Printed number. EM chipset.
KT-16 Printed number. EM chipset. STD-PCPS Proximity card. Printed number. EM chipset. With punched slot.
KT-16BL Printed number. EM chipset.
KT-10 R C Proximity tag. Printed number. EM chipset. KT-16 Printed number. EM chipset.
KT-10 Y C Proximity tag. Printed number. EM chipset. KT-16BL Printed number. EM chipset.
KT-10 G C Proximity tag. Printed number. EM chipset.
KT-10BC Proximity tag. Printed number. EM chipset. KT-15EM Key ring proximity tag. Printed number. EM chipset.
All dimensions in mm
Setting the Standard in Access Control
ACCESS CONTROL
ACCESS CONTROL
28
All dimensions in mm | Setting the Standard in Access Control
You're safe ordering with ICS Security Solutions? ICS are importers and manufacturers of security equipment. We have over 50 years of knowledge and experience in the industry, including
15 years of working onsite in installation environments.
It’s Easy! Contact our dedicated technical and sales team by any of the means below before 4pm, and your order will be dispatched on our next day Standard Delivery Service to be with you by 6pm. Tel: 01604 879300 Fax: 01604 859545 Email: orderline@icssecurity.co.uk
DELIVERY STANDARD Up to 6.00pm
REQUIRE DELIVERY BEFORE 6 PM, THEN WHY NOT UPGRADE TO ONE OF OUR EXPRESS SERVICES.
EXPRESS SAVER
EXPRESS TIMED
EXPRESS SATURDAY
Saturday Delivery
Pre Noon
Pre 10.30am
NOTE: All prices for packages up to 60kg.
Please call ICS for our most up to date Standard and Express delivery charges.
“Setting the Standard in Access Control”
Made with FlippingBook Online newsletter creator