FIRE RATED_Part1
F I R E R A T E D
F I R E R A T E D
Monitored Electric Lock
6 7 8
Monitored Electric Release
Electric Dropbolt
Door Retaining Magnets
9 -11
Micro Shear Lock
12
Mini Magnets
14 - 21 22 - 29
Standard Magnets
Door Loops
30
FIRE RATED
FR-A10001 Unmonitored Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 600lbs (272Kg) • Electro-less Nickel Plated Armature • Fail-Safe
BS EN1634:1
OPTIONS
300BP
U320M
A300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
+
250
+
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard
1
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10001DSU Unmonitored with Door Status Mini Magnet FR-A10001DS
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate
• Door status: An independent contact that works separately from the magnet to show door status not lock status
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
+
250
+
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
2
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED PRODUCTS
FIRE RATED
FR-A10002 Monitored Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 600lbs (272Kg) • Electro-less Nickel Plated Armature • Fail-Safe • Status LED ● Red ● Green
BS EN1634:1
OPTIONS
300BP
U320M
A300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
Contact
+
250
+
N.O.
N.C.
C
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard
3
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10002DSU Monitored with Door Status Mini Magnet FR-A10002DS
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status • Status LED ● Red ● Green
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
Contact
+
250
+
N.O.
N.C.
C
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
4
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10004 Unmonitored Double Mini Magnet FR-A10004
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
UK FIRE TESTED
• Aluminium housing • Safety bolts fitted
DOORS BS EN1634:1 FD30 & FD60
• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
+
11
500
+
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
5
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10004DSU Unmonitored with Door Status Double Mini Magnet FR-A10004DS
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
• Fail-Safe • 1 Hour UK fire certificate • Door status: An independent
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
contact that works separately from the magnet to show door status not lock status
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
+
11
500
+
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
6
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10005 Monitored Double Mini Magnet FR-A10005
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
UK FIRE TESTED
• Aluminium housing • Safety bolts fitted
DOORS BS EN1634:1 FD30 & FD60
• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
BS EN1634:1
• 1 Hour UK fire certificate • Status LED ● Red ● Green
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
Contact
+
11
500
+
N.O.
N.C.
C
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) . •
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
7
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10005DSU Monitored with Door Status Double Mini Magnet FR-A10005DS
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
• 1 Hour UK fire certificate • Door status: An independent
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
contact that works separately from the magnet to show door status not lock status
• Status LED
BS EN1634:1
● Red ● Green
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
Contact
+
11
500
+
N.O.
N.C.
C
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
8
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED PRODUCTS
FIRE RATED
FR-A10010 Unmonitored Standard Magnet • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
BS EN1634:1
OPTIONS
500BP
U520S
A500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
+
268
+
9
17
JP1
67
185
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
61
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .
All dimensions in mm
Setting the Standard
9
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10010DSU Unmonitored with Door Status Standard Magnet FR-A10010DS
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status
BS EN1634:1
OPTIONS
500BP
U520S
U500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
DS
+
268
+
9
17
JP1
67
185
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
61
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .
FIRE RATED
10
All dimensions in mm | Setting the Standard in Access Control
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED PRODUCTS
FIRE RATED
FR-A10020 Monitored Standard Magnet • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • Status LED ● Red ● Green
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
BS EN1634:1
OPTIONS
500BP
U520S
A500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
Contact
+
268
+
N.O.
N.C.
C
9
17
JP1
67
185
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
61
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .
All dimensions in mm
Setting the Standard
11
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10020DSU Monitored with Door Status Standard Magnet FR-A10020DS
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate
• Door status: An independent contact that works separately from the magnet to show
door status not lock status • Status LED ● Red ● Green
BS EN1634:1
OPTIONS
500BP
U520S
U500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
DS
Contact
+
268
+
N.O.
N.C.
C
9
17
JP1
67
185
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
61
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
12
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED PRODUCTS
FIRE RATED
FR-A10040 Monitored Double Standard Magnet
• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 X 1200lbs (544Kg) • Electro-less nickel plated armature • Status LED ● Red ● Green
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
BS EN1634:1
OPTIONS
500BP
U520S
A500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
Contact
+
532
+
N.O.
N.C.
C
185
17
61
9
JP1
67
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .
All dimensions in mm
Setting the Standard
13
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10040DSU Monitored with Door Status Double Standard Magnet FR-A10040DS
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 X 1200lbs (544Kg) • Electro-less nickel plated armature
• 1 Hour UK fire certificate • Door status: An independent
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
contact that works separately from the magnet to show door status not lock status
• Status LED
BS EN1634:1
● Red ● Green
OPTIONS
500BP
U520S
U500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
DS
Contact
+
532
+
N.O.
N.C.
C
185
17
61
9
JP1
67
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
14
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED PRODUCTS
FIRE RATED
FR-A10060 Unmonitored Double Standard Magnet
• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 x 1200lbs (544Kg) • Electro-less nickel plated armature
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
BS EN1634:1
OPTIONS
500BP
U520S
A 500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
+
532
+
185
17
61
9
JP1
67
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .
All dimensions in mm
Setting the Standard
15
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-EB300 Electric Dropbolt
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rating • Operating voltage 12Vdc • Fail-Safe (Power to Lock) • Auto-relocking timer delay: 0, 3, 6 and 9 seconds • 1 Hour UK fire certificate
BS EN1634:1
AUTO RELOCKING TIMER SETTINGS
Use jumpers to adjust the time between 0 to 9 seconds for door locking time delay. This is the time, which takes the dropbolt to automatically lock after the door is closed.
56
ON 1 2
ON 1 2
166
32 2
0 Seconds
3 Seconds
ON 1 2
1 2
ON
6 Seconds
9 Seconds
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: Pull in 0.9A, Holding 0.3A at 12Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Door position status output indicates door opened or closed status (Reed rated 0.25A at 30Vdc) .
• Humidity: 0 ~ 95% non-condensing. • Horizontal or vertical installation.
• Tested to 500,000 cycles • Weight: 1.2kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
16
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
UK TESTED TO BS EN1155
FR-GD650S-12 12 VDC FR-GD650S-24 24 VDC Door Retaining Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rating • Stainless Steel
• Electrically tested: BS EN1155 • Operating voltage 12 or 24Vdc • Up to 70lbs (32kg) holding force • Over-ride switch • Flush mount • 1 Hour UK fire certificate
STAINLESS STEEL
BS EN1634:1
BS EN1155
35
DOOR CLOSER
85
85
Power Input (12 or 24Vdc) from re ghting system
65
40
DOOR
43
65
WALL
SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 150mA at 12Vdc, 70mA at 24Vdc (at temperature 20°C) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.
• Weight: 380g (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
17
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
UK TESTED TO BS EN1155
FR-GD830F-12 12 VDC FR-GD830F-24 24 VDC Door Retaining Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 +FD60 Rating • Operating voltage 12 or 24Vdc • Black powder-coat finish • Up to 80lbs (36kg) holding force • Electrically tested - BS EN1155 • Over-ride switch • Floor mount • 1 Hour UK fire certificate
BS EN1634:1 BS EN1155
DOOR CLOSER
Push Off Button
65
65
105
65
Power Input (12 or 24Vdc) from re ghting system
40
DOOR
103
43
70
SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 130mA at 12Vdc, 60mA at 24Vdc (at temperature 20°C) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.
• Weight: 380g (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
18
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
UK TESTED TO BS EN1155
FR-GD830S-12 12 VDC FR-GD830S-24 24 VDC Door Retaining Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 +FD60 Rating • Operating voltage 12 or 24Vdc • Black powder-coat finish • Up to 80lbs (36kg) holding force • Electrically tested: BS EN1155 • Over-ride switch • Surface mount • 1 Hour UK fire certificate
BS EN1634:1 BS EN1155
90
DOOR CLOSER
Push Off Button
34
65
Power Input (12 or 24Vdc) from re ghting system
65
44
DOOR
43
65
WALL
SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 130mA at 12Vdc, 60mA at 24Vdc (at temperature 20°C) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.
• Weight: 380g (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
19
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FR-GK231M-L LEFT HAND FR-GK231M-R RIGHT HAND Monitored Electric Release
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rating • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • 1500lbs holding force • 500lbs side-load • 1 Hour UK fire certificate
SIDELOAD 500
LBS
UK FIRE TESTED
BS EN1634:1 STAINLESS STEEL
40
56
66
54
Operating Voltage
Power Supply
+ −
+ −
N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1
FAIL-SECURE: N.C. CONTACT FAIL-SAFE: N.O. CONTACT
J2
Lock Status Output
141
(Lock status output: 1/125Vac)
48
48
60
FAIL-SECURE: N.O. CONTACT FAIL-SAFE: N.C. CONTACT
J1
Door Status Output
13
(Door status output: 1/125Vac)
13
23
SPECIFICATION • Voltage tolerance: ±20%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Life rating of solenoid valve: 250,000 cycles.
• Keeper width: 48mm. • Latch throw: 15mm. • Material: Stainless Steel. • 1500lbs jaw strength pull testing. • Weight: 673g
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
20
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FR-GK450-ST Fire Rated ANSI Strike
UK FIRE TESTED BS EN1634:1 FD30 & FD60 DOORS
• Non Handed Fully Reversible • 1500lbs (680kg Holding Force) • Brushed Stainless Steel • Fire Rated to FD30 & FD60 (UK tested) • Fail Safe/Fail Secure Reversible • Includes intumescent strip
Fail-safe or fail-secure is field reversible by reversing the round screw. CHANGING FAIL-SAFE / FAIL-SECURE
1 3/16” (29.5mm)
Fail-safe when '1' facing up.
Fail-secure when '2' facing up.
4 ⁷/8” (123.8mm)
4 1/8” (105mm)
1 3/4” (45mm)
3 3/8” (85mm)
LIP EXTENSIONS (OPTION)
25mm
50mm
11/16” (17mm)
1/8” (3mm) 1 ¼” (31.75mm)
1 11/16” (43.5mm)
LP-050 2" (50mm)
LP-025 1" (25mm)
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
21
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-GK450M-ST Fire Rated ANSI Strike • Non Handed Fully Reversible • 1500lbs (680kg Holding Force) • Brushed Stainless Steel • Fire Rated to FD30 & FD60 (UK tested) • Fail Safe/Fail Secure Reversible • Monitored • Includes intumescent strip
UK FIRE TESTED BS EN1634:1 FD30 & FD60 DOORS
Fail-safe or fail-secure is field reversible by reversing the round screw. CHANGING FAIL-SAFE / FAIL-SECURE
1 3/16” (29.5mm)
Fail-safe when '1' facing up.
Fail-secure when '2' facing up.
4 ⁷/8” (123.8mm)
4 1/8” (105mm)
1 3/4” (45mm)
3 3/8” (85mm)
LIP EXTENSIONS (OPTION)
25mm
50mm
11/16” (17mm)
1/8” (3mm) 1 ¼” (31.75mm)
1 11/16” (43.5mm)
LP-050 2" (50mm)
LP-025 1" (25mm)
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
22
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FR-SL500 Micro Shear-Lock
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rating • Operating voltage 12~24Vdc
• Holding force up to 2,600lbs (1,200Kg) in shear • Locking time delay: 0.5 to 25 seconds (Adjustable) • N.C/N.O/Com • 1 Hour UK fire certificate
BS EN1634:1
This product must be fitted with the intumescent pack provided
INTUMESCENT PACK
25
137
182
Reader
Exit Button
30
135
N.O.
COM.
N.C.
30
N.C.
COM.
24
Power Supply
Black
+ −
Red
DC 12 or 24V
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
23
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-ML350 Monitored Electric Lock • FD30 + FD60 Rating • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-safe • 1500lbs holding force • 500lbs side-load • 1 Hour UK fire certificate
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
SIDELOAD 500
LBS
BS EN1634:1 STAINLESS STEEL
UK FIRE TESTED
40
Operating Voltage
Power Supply
+ −
+ −
N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1
141
BOND SENSOR SWITCH
J2
Lock Bolt Sensor Output
N.C.: Unlocked N.O.: Locked
186
1A/125Vac (Lock status output: 1A/125Vac)
200
DOOR STATUS SWITCH
J1
N.C.: Unlocked N.O.: Locked
Door Status Output
1A/125Vac (Door status output: 1A/125Vac)
}
JP3: Control ML-350 to be locked by door status.
It is applied to fail-safe mode only.
JP3: Power to lock without any devices.
25
3
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
24
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATE
FIRE RATED
FR -ML 450M Monitored Electric Lock • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • Fire resistant • 1500lbs holding force • 500lbs side-load
FR -ML 450M Monitored Electric Lock • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • Fire resistant • 1500lbs holding force • 500lbs side-load
UK FIRE TESTED
UK FIRE TESTED
BS EN1634:1 FD30 & FD60 DOORS
BS EN1634:1 FD30 & FD60 DOORS
SIDELOAD 500
SIDELO 500
LBS
FIRE RESISTANT
STAINLESS STEEL
FIRE RESISTANT
STAINLESS STEEL
UK FIRE TESTED
UK FIR TESTE
25
25
24
24
Operating Voltage
Operating Voltage
Power Supply
Power Supply
+ −
+ −
+ −
+ −
N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1
J2 N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1 J1
BOND SENSOR SWITCH
BOND SENSOR SWITCH
J2
Lock Bolt Sensor Output
Lock Bolt Sensor Output
210
210
N.C.: Unlocked N.O.: Locked
N.C.: Unlocked N.O.: Locked
160
160
185
185
1A/125Vac (Lock status output: 1A/125Vac)
1A/125Vac (Lock status output: 1A/125Vac)
DOOR STATUS SWITCH
DOOR STATUS SWITCH
J1
N.C.: Unlocked N.O.: Locked
N.C.: Unlocked N.O.: Locked
Door Status Output
Door Status Output
1A/125Vac (Door status output: 1A/125Vac)
1A/125Vac (Door status output: 1A/125Vac)
JP3: Control ML-350 to be locked by door status.
JP3: Control ML-350 to be locked by door status.
It is applied to fail-safe mode only.
It is applied to fail-safe mode only.
40.5
40.5
3
3
JP3: Power to lock without any devices.
JP3: Power to lock without any devices.
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .
• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .
All dimensions in mm
All dimensions in mm
Setting the Standard in Access Control
Setting the Standard in Access Con
Electric locking
Electric locking
25
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
Electric Lock
BS EN1634:1
• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 x 600lbs (272Kg) • Electro-less Nickel Plated Armature • Status LED ● Red ● Green
3mm (1/8”)
30mm (1 3/16”)
140mm (5 33/64”)
160mm (6 19/64”)
96mm (3 25/32”)
47mm (1 55/64”)
10mm (25/64”)
Door Gap 6mm (1/4 inch) maximum
Voltage at lock 12-24VDC ±15%
Compliance & Certification • CE Compliant, RoHS 2 Compliant • FCC Part 15 / IC Compliant • RCM Compliant, UL Listed • EN 14846:2008 Certified • Suitable for use on fire resistant doorsets
Static strength 10,000N (2,250 lbf)
Current usage Holding: 40mA@12VDC, 25mA@24VDC Maximum: 0.75A@12VDC, 0.4A@24VDC
Sideload (release on request) 6,000N (1,350 lbf)
Endurance Cycle tested to 1,000,000 operations Bolt Pin 10mm (3/8 inch) thick, 13mm (1/2 inch) extension Alignment 8mm (5/16 inch) misalignment correction
Monitor switch ratings 30VDC max, 100mA max
Materials Lock/Strike Plate: Stainless Steel 304 Bolt Pin: Stainless Steel 17-4PH
Environment IP53
All dimensions in mm
Setting the Standard
FIRE RATED
26
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FR-U10001 Unmonitored Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
+
250
+
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
27
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10001DSU Unmonitored with Door Status Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate
• Door status: An independent contact that works separately from the magnet to show door status not lock status
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
+
250
+
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
28
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FR-U10002 Monitored Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe
• 1 Hour UK fire certificate • Status LED ● Red ● Green
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
Contact
+
250
+
N.O.
N.C.
C
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
29
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10002DSU Monitored with Door Status Mini Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status • Status LED ● Red ● Green
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
Contact
+
250
+
N.O.
N.C.
C
11
6
JP1
42
180
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
38
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output
door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
30
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10004 Unmonitored Double Mini Magnet
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
UK FIRE TESTED
• Aluminium housing • Safety bolts fitted
DOORS BS EN1634:1 FD30 & FD60
• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
+
11
500
+
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
31
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10004DSU Unmonitored with Door Status Double Mini Magnet
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
• Fail-Safe • 1 Hour UK fire certificate • Door status: An independent
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
contact that works separately from the magnet to show door status not lock status
BS EN1634:1
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
+
11
500
+
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
32
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10005 Monitored Double Mini Magnet
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
UK FIRE TESTED
• Aluminium housing • Safety bolts fitted
DOORS BS EN1634:1 FD30 & FD60
• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
BS EN1634:1
• 1 Hour UK fire certificate • Status LED ● Red ● Green
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
Contact
+
11
500
+
N.O.
N.C.
C
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) . •
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
33
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10005DSU Monitored with Door Status Double Mini Magnet
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature
• 1 Hour UK fire certificate • Door status: An independent
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
contact that works separately from the magnet to show door status not lock status
• Status LED
BS EN1634:1
● Red ● Green
OPTIONS
300BP
U320M
U300ZL
300ZLDC
U300AL
UGDB14
LD-MM-SC
Power Supply
DS
Contact
+
11
500
+
N.O.
N.C.
C
180
38
JP1
6
42
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
26
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .
• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) .
• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
FIRE RATED
34
All dimensions in mm | Setting the Standard in Access Control
FIRE RATED
FIRE RATED
FR-U10010 Unmonitored Standard Magnet
UK FIRE TESTED
DOORS BS EN1634:1 FD30 & FD60
• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)
• Aluminium housing • Safety bolts fitted
• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate
BS EN1634:1
OPTIONS
500BP
U520S
U500ZL
500ZLDC
U500AL
LD-SM-SC
Power Supply
+
268
+
9
17
JP1
67
185
CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.
40
61
12Vdc 24Vdc
SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .
• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .
All dimensions in mm
Setting the Standard in Access Control
FIRE RATED
35
FIRE RATED
All dimensions in mm | Setting the Standard in Access Control
Made with FlippingBook - professional solution for displaying marketing and sales documents online