FIRE RATED_Part1

F I R E R A T E D

F I R E R A T E D

Monitored Electric Lock

6 7 8

Monitored Electric Release

Electric Dropbolt

Door Retaining Magnets

9 -11

Micro Shear Lock

12

Mini Magnets

14 - 21 22 - 29

Standard Magnets

Door Loops

30

FIRE RATED

FR-A10001 Unmonitored Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 600lbs (272Kg) • Electro-less Nickel Plated Armature • Fail-Safe

BS EN1634:1

OPTIONS

300BP

U320M

A300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

+

250

+

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard

1

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10001DSU Unmonitored with Door Status Mini Magnet FR-A10001DS

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate

• Door status: An independent contact that works separately from the magnet to show door status not lock status

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

+

250

+

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

2

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED PRODUCTS

FIRE RATED

FR-A10002 Monitored Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 600lbs (272Kg) • Electro-less Nickel Plated Armature • Fail-Safe • Status LED ● Red ● Green

BS EN1634:1

OPTIONS

300BP

U320M

A300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

Contact

+

250

+

N.O.

N.C.

C

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard

3

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10002DSU Monitored with Door Status Mini Magnet FR-A10002DS

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status • Status LED ● Red ● Green

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

Contact

+

250

+

N.O.

N.C.

C

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

4

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10004 Unmonitored Double Mini Magnet FR-A10004

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

UK FIRE TESTED

• Aluminium housing • Safety bolts fitted

DOORS BS EN1634:1 FD30 & FD60

• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

+

11

500

+

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

5

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10004DSU Unmonitored with Door Status Double Mini Magnet FR-A10004DS

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

• Fail-Safe • 1 Hour UK fire certificate • Door status: An independent

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

contact that works separately from the magnet to show door status not lock status

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

+

11

500

+

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

6

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10005 Monitored Double Mini Magnet FR-A10005

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

UK FIRE TESTED

• Aluminium housing • Safety bolts fitted

DOORS BS EN1634:1 FD30 & FD60

• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

BS EN1634:1

• 1 Hour UK fire certificate • Status LED ● Red ● Green

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

Contact

+

11

500

+

N.O.

N.C.

C

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) . •

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

7

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10005DSU Monitored with Door Status Double Mini Magnet FR-A10005DS

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

• 1 Hour UK fire certificate • Door status: An independent

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

contact that works separately from the magnet to show door status not lock status

• Status LED

BS EN1634:1

● Red ● Green

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

Contact

+

11

500

+

N.O.

N.C.

C

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

8

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED PRODUCTS

FIRE RATED

FR-A10010 Unmonitored Standard Magnet • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

BS EN1634:1

OPTIONS

500BP

U520S

A500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

+

268

+

9

17

JP1

67

185

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

61

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .

All dimensions in mm

Setting the Standard

9

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10010DSU Unmonitored with Door Status Standard Magnet FR-A10010DS

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status

BS EN1634:1

OPTIONS

500BP

U520S

U500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

DS

+

268

+

9

17

JP1

67

185

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

61

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .

FIRE RATED

10

All dimensions in mm | Setting the Standard in Access Control

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED PRODUCTS

FIRE RATED

FR-A10020 Monitored Standard Magnet • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • Status LED ● Red ● Green

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

BS EN1634:1

OPTIONS

500BP

U520S

A500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

Contact

+

268

+

N.O.

N.C.

C

9

17

JP1

67

185

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

61

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .

All dimensions in mm

Setting the Standard

11

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10020DSU Monitored with Door Status Standard Magnet FR-A10020DS

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate

• Door status: An independent contact that works separately from the magnet to show

door status not lock status • Status LED ● Red ● Green

BS EN1634:1

OPTIONS

500BP

U520S

U500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

DS

Contact

+

268

+

N.O.

N.C.

C

9

17

JP1

67

185

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

61

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

12

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED PRODUCTS

FIRE RATED

FR-A10040 Monitored Double Standard Magnet

• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 X 1200lbs (544Kg) • Electro-less nickel plated armature • Status LED ● Red ● Green

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

BS EN1634:1

OPTIONS

500BP

U520S

A500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

Contact

+

532

+

N.O.

N.C.

C

185

17

61

9

JP1

67

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .

All dimensions in mm

Setting the Standard

13

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10040DSU Monitored with Door Status Double Standard Magnet FR-A10040DS

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 X 1200lbs (544Kg) • Electro-less nickel plated armature

• 1 Hour UK fire certificate • Door status: An independent

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

contact that works separately from the magnet to show door status not lock status

• Status LED

BS EN1634:1

● Red ● Green

OPTIONS

500BP

U520S

U500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

DS

Contact

+

532

+

N.O.

N.C.

C

185

17

61

9

JP1

67

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

14

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED PRODUCTS

FIRE RATED

FR-A10060 Unmonitored Double Standard Magnet

• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 x 1200lbs (544Kg) • Electro-less nickel plated armature

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

BS EN1634:1

OPTIONS

500BP

U520S

A 500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

+

532

+

185

17

61

9

JP1

67

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight:9.3kg (approx) .

All dimensions in mm

Setting the Standard

15

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-EB300 Electric Dropbolt

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rating • Operating voltage 12Vdc • Fail-Safe (Power to Lock) • Auto-relocking timer delay: 0, 3, 6 and 9 seconds • 1 Hour UK fire certificate

BS EN1634:1

AUTO RELOCKING TIMER SETTINGS

Use jumpers to adjust the time between 0 to 9 seconds for door locking time delay. This is the time, which takes the dropbolt to automatically lock after the door is closed.

56

ON 1 2

ON 1 2

166

32 2

0 Seconds

3 Seconds

ON 1 2

1 2

ON

6 Seconds

9 Seconds

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: Pull in 0.9A, Holding 0.3A at 12Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Door position status output indicates door opened or closed status (Reed rated 0.25A at 30Vdc) .

• Humidity: 0 ~ 95% non-condensing. • Horizontal or vertical installation.

• Tested to 500,000 cycles • Weight: 1.2kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

16

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

UK TESTED TO BS EN1155

FR-GD650S-12 12 VDC FR-GD650S-24 24 VDC Door Retaining Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rating • Stainless Steel

• Electrically tested: BS EN1155 • Operating voltage 12 or 24Vdc • Up to 70lbs (32kg) holding force • Over-ride switch • Flush mount • 1 Hour UK fire certificate

STAINLESS STEEL

BS EN1634:1

BS EN1155

35

DOOR CLOSER

85

85

Power Input (12 or 24Vdc) from re ghting system

65

40

DOOR

43

65

WALL

SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 150mA at 12Vdc, 70mA at 24Vdc (at temperature 20°C) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.

• Weight: 380g (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

17

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

UK TESTED TO BS EN1155

FR-GD830F-12 12 VDC FR-GD830F-24 24 VDC Door Retaining Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 +FD60 Rating • Operating voltage 12 or 24Vdc • Black powder-coat finish • Up to 80lbs (36kg) holding force • Electrically tested - BS EN1155 • Over-ride switch • Floor mount • 1 Hour UK fire certificate

BS EN1634:1 BS EN1155

DOOR CLOSER

Push Off Button

65

65

105

65

Power Input (12 or 24Vdc) from re ghting system

40

DOOR

103

43

70

SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 130mA at 12Vdc, 60mA at 24Vdc (at temperature 20°C) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.

• Weight: 380g (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

18

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

UK TESTED TO BS EN1155

FR-GD830S-12 12 VDC FR-GD830S-24 24 VDC Door Retaining Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 +FD60 Rating • Operating voltage 12 or 24Vdc • Black powder-coat finish • Up to 80lbs (36kg) holding force • Electrically tested: BS EN1155 • Over-ride switch • Surface mount • 1 Hour UK fire certificate

BS EN1634:1 BS EN1155

90

DOOR CLOSER

Push Off Button

34

65

Power Input (12 or 24Vdc) from re ghting system

65

44

DOOR

43

65

WALL

SPECIFICATION • Voltage tolerance: ±15%. • Current draw: 130mA at 12Vdc, 60mA at 24Vdc (at temperature 20°C) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Humidity: 0 ~ 95% non-condensing.

• Weight: 380g (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

19

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FR-GK231M-L LEFT HAND FR-GK231M-R RIGHT HAND Monitored Electric Release

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rating • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • 1500lbs holding force • 500lbs side-load • 1 Hour UK fire certificate

SIDELOAD 500

LBS

UK FIRE TESTED

BS EN1634:1 STAINLESS STEEL

40

56

66

54

Operating Voltage

Power Supply

+ −

+ −

N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1

FAIL-SECURE: N.C. CONTACT FAIL-SAFE: N.O. CONTACT

J2

Lock Status Output

141

(Lock status output: 1/125Vac)

48

48

60

FAIL-SECURE: N.O. CONTACT FAIL-SAFE: N.C. CONTACT

J1

Door Status Output

13

(Door status output: 1/125Vac)

13

23

SPECIFICATION • Voltage tolerance: ±20%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 45°C (14 to 131°F) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Life rating of solenoid valve: 250,000 cycles.

• Keeper width: 48mm. • Latch throw: 15mm. • Material: Stainless Steel. • 1500lbs jaw strength pull testing. • Weight: 673g

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

20

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FR-GK450-ST Fire Rated ANSI Strike

UK FIRE TESTED BS EN1634:1 FD30 & FD60 DOORS

• Non Handed Fully Reversible • 1500lbs (680kg Holding Force) • Brushed Stainless Steel • Fire Rated to FD30 & FD60 (UK tested) • Fail Safe/Fail Secure Reversible • Includes intumescent strip

Fail-safe or fail-secure is field reversible by reversing the round screw. CHANGING FAIL-SAFE / FAIL-SECURE

1 3/16” (29.5mm)

Fail-safe when '1' facing up.

Fail-secure when '2' facing up.

4 ⁷/8” (123.8mm)

4 1/8” (105mm)

1 3/4” (45mm)

3 3/8” (85mm)

LIP EXTENSIONS (OPTION)

25mm

50mm

11/16” (17mm)

1/8” (3mm) 1 ¼” (31.75mm)

1 11/16” (43.5mm)

LP-050 2" (50mm)

LP-025 1" (25mm)

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

21

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-GK450M-ST Fire Rated ANSI Strike • Non Handed Fully Reversible • 1500lbs (680kg Holding Force) • Brushed Stainless Steel • Fire Rated to FD30 & FD60 (UK tested) • Fail Safe/Fail Secure Reversible • Monitored • Includes intumescent strip

UK FIRE TESTED BS EN1634:1 FD30 & FD60 DOORS

Fail-safe or fail-secure is field reversible by reversing the round screw. CHANGING FAIL-SAFE / FAIL-SECURE

1 3/16” (29.5mm)

Fail-safe when '1' facing up.

Fail-secure when '2' facing up.

4 ⁷/8” (123.8mm)

4 1/8” (105mm)

1 3/4” (45mm)

3 3/8” (85mm)

LIP EXTENSIONS (OPTION)

25mm

50mm

11/16” (17mm)

1/8” (3mm) 1 ¼” (31.75mm)

1 11/16” (43.5mm)

LP-050 2" (50mm)

LP-025 1" (25mm)

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

22

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FR-SL500 Micro Shear-Lock

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rating • Operating voltage 12~24Vdc

• Holding force up to 2,600lbs (1,200Kg) in shear • Locking time delay: 0.5 to 25 seconds (Adjustable) • N.C/N.O/Com • 1 Hour UK fire certificate

BS EN1634:1

This product must be fitted with the intumescent pack provided

INTUMESCENT PACK

25

137

182

Reader

Exit Button

30

135

N.O.

COM.

N.C.

30

N.C.

COM.

24

Power Supply

Black

+ −

Red

DC 12 or 24V

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

23

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-ML350 Monitored Electric Lock • FD30 + FD60 Rating • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-safe • 1500lbs holding force • 500lbs side-load • 1 Hour UK fire certificate

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

SIDELOAD 500

LBS

BS EN1634:1 STAINLESS STEEL

UK FIRE TESTED

40

Operating Voltage

Power Supply

+ −

+ −

N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1

141

BOND SENSOR SWITCH

J2

Lock Bolt Sensor Output

N.C.: Unlocked N.O.: Locked

186

1A/125Vac (Lock status output: 1A/125Vac)

200

DOOR STATUS SWITCH

J1

N.C.: Unlocked N.O.: Locked

Door Status Output

1A/125Vac (Door status output: 1A/125Vac)

}

JP3: Control ML-350 to be locked by door status.

It is applied to fail-safe mode only.

JP3: Power to lock without any devices.

25

3

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

24

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATE

FIRE RATED

FR -ML 450M Monitored Electric Lock • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • Fire resistant • 1500lbs holding force • 500lbs side-load

FR -ML 450M Monitored Electric Lock • Operating voltage 12Vdc (24Vdc available to order) • Stainless Steel • Fail-Safe • Fire resistant • 1500lbs holding force • 500lbs side-load

UK FIRE TESTED

UK FIRE TESTED

BS EN1634:1 FD30 & FD60 DOORS

BS EN1634:1 FD30 & FD60 DOORS

SIDELOAD 500

SIDELO 500

LBS

FIRE RESISTANT

STAINLESS STEEL

FIRE RESISTANT

STAINLESS STEEL

UK FIRE TESTED

UK FIR TESTE

25

25

24

24

Operating Voltage

Operating Voltage

Power Supply

Power Supply

+ −

+ −

+ −

+ −

N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1

J2 N.O.2 C.2 N.C.2 N.O.1 C.1 N.C.1 J1

BOND SENSOR SWITCH

BOND SENSOR SWITCH

J2

Lock Bolt Sensor Output

Lock Bolt Sensor Output

210

210

N.C.: Unlocked N.O.: Locked

N.C.: Unlocked N.O.: Locked

160

160

185

185

1A/125Vac (Lock status output: 1A/125Vac)

1A/125Vac (Lock status output: 1A/125Vac)

DOOR STATUS SWITCH

DOOR STATUS SWITCH

J1

N.C.: Unlocked N.O.: Locked

N.C.: Unlocked N.O.: Locked

Door Status Output

Door Status Output

1A/125Vac (Door status output: 1A/125Vac)

1A/125Vac (Door status output: 1A/125Vac)

JP3: Control ML-350 to be locked by door status.

JP3: Control ML-350 to be locked by door status.

It is applied to fail-safe mode only.

It is applied to fail-safe mode only.

40.5

40.5

3

3

JP3: Power to lock without any devices.

JP3: Power to lock without any devices.

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 280mA at 12Vdc, 140mA at 24Vdc (at temperature 20°C) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Operating temperature: -10 ~ 45°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .

• Humidity: 0 ~ 95% non-condensing. • Solenoids tested to 250,000 cycles. • Weight: 673g (approx) .

All dimensions in mm

All dimensions in mm

Setting the Standard in Access Control

Setting the Standard in Access Con

Electric locking

Electric locking

25

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

Electric Lock

BS EN1634:1

• Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Holding force up to 2 x 600lbs (272Kg) • Electro-less Nickel Plated Armature • Status LED ● Red ● Green

3mm (1/8”)

30mm (1 3/16”)

140mm (5 33/64”)

160mm (6 19/64”)

96mm (3 25/32”)

47mm (1 55/64”)

10mm (25/64”)

Door Gap 6mm (1/4 inch) maximum

Voltage at lock 12-24VDC ±15%

Compliance & Certification • CE Compliant, RoHS 2 Compliant • FCC Part 15 / IC Compliant • RCM Compliant, UL Listed • EN 14846:2008 Certified • Suitable for use on fire resistant doorsets

Static strength 10,000N (2,250 lbf)

Current usage Holding: 40mA@12VDC, 25mA@24VDC Maximum: 0.75A@12VDC, 0.4A@24VDC

Sideload (release on request) 6,000N (1,350 lbf)

Endurance Cycle tested to 1,000,000 operations Bolt Pin 10mm (3/8 inch) thick, 13mm (1/2 inch) extension Alignment 8mm (5/16 inch) misalignment correction

Monitor switch ratings 30VDC max, 100mA max

Materials Lock/Strike Plate: Stainless Steel 304 Bolt Pin: Stainless Steel 17-4PH

Environment IP53

All dimensions in mm

Setting the Standard

FIRE RATED

26

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FR-U10001 Unmonitored Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

+

250

+

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

27

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10001DSU Unmonitored with Door Status Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate

• Door status: An independent contact that works separately from the magnet to show door status not lock status

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

+

250

+

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

28

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FR-U10002 Monitored Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe

• 1 Hour UK fire certificate • Status LED ● Red ● Green

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

Contact

+

250

+

N.O.

N.C.

C

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

29

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10002DSU Monitored with Door Status Mini Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate • Door status: An independent contact that works separately from the magnet to show door status not lock status • Status LED ● Red ● Green

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

Contact

+

250

+

N.O.

N.C.

C

11

6

JP1

42

180

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

38

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output

door closed) (SPDT rated 0.25A at 12Vdc) . • Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 2.0kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

30

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10004 Unmonitored Double Mini Magnet

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

UK FIRE TESTED

• Aluminium housing • Safety bolts fitted

DOORS BS EN1634:1 FD30 & FD60

• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature • Fail-Safe • 1 Hour UK fire certificate

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

+

11

500

+

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

31

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10004DSU Unmonitored with Door Status Double Mini Magnet

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

• Fail-Safe • 1 Hour UK fire certificate • Door status: An independent

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

contact that works separately from the magnet to show door status not lock status

BS EN1634:1

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

+

11

500

+

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 3.7kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

32

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10005 Monitored Double Mini Magnet

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

UK FIRE TESTED

• Aluminium housing • Safety bolts fitted

DOORS BS EN1634:1 FD30 & FD60

• Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

BS EN1634:1

• 1 Hour UK fire certificate • Status LED ● Red ● Green

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

Contact

+

11

500

+

N.O.

N.C.

C

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) . •

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

33

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10005DSU Monitored with Door Status Double Mini Magnet

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable) • Aluminium housing • Safety bolts fitted • Holding force up to 2 x 600lbs (272Kg) • Electro-less nickel plated armature

• 1 Hour UK fire certificate • Door status: An independent

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

contact that works separately from the magnet to show door status not lock status

• Status LED

BS EN1634:1

● Red ● Green

OPTIONS

300BP

U320M

U300ZL

300ZLDC

U300AL

UGDB14

LD-MM-SC

Power Supply

DS

Contact

+

11

500

+

N.O.

N.C.

C

180

38

JP1

6

42

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

26

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 480mA at 12Vdc, 240mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) .

• Lock’s surface temperature: Current temperature ±20% (when power is on) . • Humidity: 0 ~ 95% non-condensing. • Weight: 3.7kg (approx) .

• Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

FIRE RATED

34

All dimensions in mm | Setting the Standard in Access Control

FIRE RATED

FIRE RATED

FR-U10010 Unmonitored Standard Magnet

UK FIRE TESTED

DOORS BS EN1634:1 FD30 & FD60

• FD30 + FD60 Rated • Operating voltage 12~24Vdc (Selectable)

• Aluminium housing • Safety bolts fitted

• Holding force up to 1200lbs (544Kg) • Electro-less nickel plated armature • 1 Hour UK fire certificate

BS EN1634:1

OPTIONS

500BP

U520S

U500ZL

500ZLDC

U500AL

LD-SM-SC

Power Supply

+

268

+

9

17

JP1

67

185

CAUTION Before power on the unit, set input Voltage Selector JP1 according to the supply voltage.

40

61

12Vdc 24Vdc

SPECIFICATION • Voltage tolerance: ±10%. • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C) . • Operating temperature: -10 ~ 55°C (14 to 131°F) . • Lock’s surface temperature: Current temperature ±20% (when power is on) .

• Humidity: 0 ~ 95% non-condensing. • Aluminium housing, nickel plated armature. • Weight: 4.71kg (approx) .

All dimensions in mm

Setting the Standard in Access Control

FIRE RATED

35

FIRE RATED

All dimensions in mm | Setting the Standard in Access Control

Made with FlippingBook - professional solution for displaying marketing and sales documents online